Electrical
Input
|
Communications
|
| Nominal
Voltage |
120
Vac, autosensing (user-selectable for 100, 110, 120, &
127 Vac) |
Serial
Port
|
RS-232
communications port standard |
| Voltage
Range |
80-144V
(without using batteries) |
Communications
Cable |
6-foot
communications cable included |
| Input
Power Factor |
>.95,
typical |
ConnectUPS-M
SNMP Module (optional)** |
SNMP
card adds direct control and monitoring capabilities in
SNMP-based networks |
| Frequency |
50/60
Hz, autosensing |
Multi-Port |
Equipped
with (6) communications ports to provide serial communication
to multiple devices |
| Frequency
Range |
45-65
Hz |
USB
Module (optional)** |
Allows
UPS to communicate with Windows 98 computers via USB port;
factory-installed option only |
|
Electrical
Output
|
General
|
| On
Utility VoltageRegulation |
±3%
of nominal |
Topology |
Tru
online, double-conversion |
| On
Battery Voltage Regulation |
±3%
of nominal |
Diagnostics |
Full
system self-test on power up |
| Efficiency |
89-92%,
depending on load |
UPS
Bypass |
Automatic
on overload or UPS failure |
| Frequency
Regulation |
±3
Hz online; ±0.1 Hz on battery |
Dimensions
& Weights |
See
Model Selection Guide |
| Load
Crest Factor |
3
to 1 ratio |
|
|
Battery
|
Environmental
and Safety
|
| Internal
Battery Type |
Sealed,
lead-acid; maintenance free
700/1000 VA: (2) 12V, 9 Ah
1250-2000 VA: (4) 12V, 9 Ah |
Safety
Markings
EMC
Marking
|
UL,
CSA, and NOM
FCC Class
B and VCCI Class II
|
| EBM
Battery Type |
PW9125
25 EBM: (8) 12V, 9Ah
PW9125 48 EBM: (8) 12V,9 Ah |
Surge
Suppression |
IEEE/ANSI
C62.41 Category B (formerly 587) |
| Battery
Runtime |
See
Battery Runtimes |
Audible
Noise |
<45
dBA (on utility); <50 dBA (on battery) |
| Battery
Replacement |
Hot-swappable
internal and external batteries |
Ambient
Operating/Storage Temperature |
0
to 40°C (32 to 104°F)/
0 to 25°C (32 to 77°F) |
| Recharge
Time |
<2
hrs. from complete discharge to 80% capacity at nominal
line conditions |
Relative
Humidity |
5
to 90%, non-condensing |
| Start-On-Battery |
Allows
start of UPS without utility input |
REPO
Port |
Meets
NEC code 645-11 intent and UL requirements |
| |
Network
Transient Protector |
In
and out jack for telephone/modem protection or 10Base-T;
UL497A tested |
|
|
Series
9 Power Protection
True
Online Design
True online systems such as the Powerware 9125 are
the only type of UPSs that completely isolate connected
equipment from all 9 of the most common problems:
- Power
failures
- Sags
- Surges
- Brownouts
- Line
noise
- High
voltage spikes
- Switching
transients
- Frequency
variations
- Harmonic
distortion
|
Even
when presented with the most severe of these power probkems,
the Powerware 9125 output remains within a remarkable ±3%
of nominal voltage, meaning your critical system always
receives clean power. In addition, the Powerware 9125 transfers
to battery with no break inpower, making it the perfect
UPS for equipment in environments plagued by poor power.
Powerware® 9125 Model Selection Guide
|
Model
Number
|
Power
Out (VA/Watt)
|
Input/Output
Voltage (VAC)
|
Frequency
(Hz)
|
Input
Connection
|
Output
Receptacles
|
Dimensions
(HxWxD)
|
Weight
(Lb/Kg)
|
| PW9125
700 |
700/490
|
120
|
50/60
|
5-15P
|
(6)
5-15R
|
3.5x17.0x19.4
in
89x432x494 mm
|
34/15
|
| PW9125
1000 |
1000/700
|
120
|
50/60
|
5-15P
|
(6)
5-15R
|
3.5x17.0x19.4
in
89x432x494 mm
|
34/15
|
| PW9125
1250 |
1250/875
|
120
|
50/60
|
5-15P
|
(6)
5-15R
|
3.5x17.0x19.4
in
89x432x494 mm
|
50/23
|
| PW9125
1500 |
1500/1050
|
120
|
50/60
|
5-15P
|
(6)
5-15R
|
3.5x17.0x19.4
in
89x432x494 mm
|
50/23
|
| PW9125
2000 |
2000/1400
|
120
|
50/60
|
5-20P
|
(6)
5-15R
|
3.5x17.0x19.4
in
89x432x494 mm
|
50/23
|
| Optional
Extended Battery Modules (EBMs) |
PW9125
24 EBM
700/1000 VA models only |
-
|
-
|
-
|
Standard
Connector
|
-
|
3.5x17.0x19.4
in
89x432x494 mm
|
65/29.5
|
PW9125
48 EBM
1250-2000 VA models only |
-
|
-
|
-
|
Standard
Connector
|
-
|
3.5x17.0x19.4
in
89x432x494 mm
|
65/29.5
|
| ***Call